Potentiometer to Analog Signal Conditioners, Converters, Isolators, Transmitters, Alarms

lifetime warranty
  • Lifetime Warranty on API Modules
  • LoopTracker ® LEDs
  • Hot-Swappable Plug-In Design
  • Zero and Span Output Calibration
  • Push to Test Output
  • Full I/O/Power Isolation

Click on PDF links below
for product information

How to Order

  1. Select a model
  2. See data sheet for ordering info and options
  3. Note that options affect pricing
  4. Request a quote via chat or call us
  5. 2-5 day typical lead time + shipping time
  6. 5-10 day lead time for quantities of 5 or more + shipping time
  7. To place your order
Model
Input/Output
Features
Product

Potentiometer Input Alarm Trips


Factory Configured
APD 1800  from $289
APD 1820  from $309

Open Datasheet
Download Datasheet
Any full-range potentiometer
0-100 Ω to
0-1 Mega Ω
APD 1800 Single Alarm Trip
Dual SPDT contact sets
Standard: HI alarm, non-latching, normal acting
See data sheet for alarm options
APD 1820 Dual Alarm Trip
2 independent SPDT contact sets
Standard: HI/LO alarms, non-latching, normal acting
See data sheet for alarm options
  • User adjustable setpoint(s)
  • User adjustable deadband(s)
  • 8 Amp SPDT contacts
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO, band alarm
  • Optional reverse acting
  • Optional latching alarms
  • Push to test/reset
  • Remote push to test/reset
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount without tools
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD 1800 UL approved
APD 1800, APD 1820

Potentiometer to DC Isolated Signal Conditioner


Factory Configured
API 4003 G I  from $309

Open Datasheet
Download Datasheet
Input range
Any full-range potentiometer
0-100 Ω to 0-1 Mega Ω
Specify output range
Factory configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA
  • Hot-swappable plug-in design
  • RepalcesAction AP 4003
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 85-265 VAC, 60-300 VDC power
  • D option for 9-30 VDC power


Api 4003G I UL listed
API 4003 GI

Potentiometer to DC Isolated Signal Conditioner


Factory Configured
APD 4003  from $289

Open Datasheet
Download Datasheet
Input range
Any full-range potentiometer
0-100 Ω to 0-1 Mega Ω
Specify output range
Factory Configured
0-1 V to 0-10 V
±1 V to ±10 V
0-1 mA to 0-20 mA, 4-20 mA
  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Selectable output sink/source
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD4003 UL approved
APD 4003

Potentiometer to DC Isolated Signal Conditioner


Field Selectable Minuteman Setup


API 4008 G  from $319

Open Datasheet
Download Datasheet
Any full-range potentiometer
0-100 Ω to 0-1 Mega Ω
18 field configurable outputs
0-1 V to 0-10 V
±1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • Minuteman one-minute setup
  • Hot-swappable plug-in design
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Uses API-008 8-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option for 85-265 VAC, 60-300 VDC power
  • D option for 9-30 VDC power


Api 4008G UL listed
API 4008 G

Potentiometer to DC Isolated Signal Conditioner


Field Selectable Minuteman Setup


APD 4008  from $309

Open Datasheet
Download Datasheet
Any potentiometer
0-100 Ω to 0-1 Mega Ω
0 to 90% offset capable
Can use partial potentiometer ranges
18 field configurable outputs
0-1 V to 0-10 V
±1 V to ±10 V
0-2 mA to 0-20 mA, 4-20 mA
  • Minuteman one-minute setup
  • Removable plugs
  • I/O LoopTracker LEDs
  • Output test button
  • Full I/O/power isolation
  • Selectable output sink/source
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD 4008 UL approved
APD 4008

Universal Input to DC Isolated Signal Conditioner


Field Programmable


APD 8000  from $419

*Free I/O Range Setup*
Include your I/O ranges on your order,
and we'll set it up for you!
Open Datasheet
Download Datasheet
Open Feature Summary
Download Feature Summary
Field configurable inputs
DC volts: 35 ranges from ±25mVDC to ±10 VDC
DC mA sinking input, 20 ranges from ±0.5mADC to ±20mADC
Potentiometer: 100Ω min. to 1 MegaΩ max.
Thermocouple: J, K, T, E, R, S, N, B, C, D, G, M, P
RTDs: 2, 3, or 4 wire, 10Ω to 8000Ω RTDs
Thermistor: 44000 series, YSI 400, Spectrum
Custom input available
18 field programmable output ranges
Voltage: 0-1V, 0-2V, 0-4V, 0-5V, 1-5V, 0-8V, 0-10V, 2-10V,
±5V, ±10V
Current: 0-2mA, 0-4mA, 0-8mA, 0-10mA, 2-10mA, 0-16mA,
0-20mA, 4-20mA
Can be wired for sink or source
  • Switch and pushbutton setup
  • Removable plugs
  • Input LoopTracker LED
  • Output test button
  • Full I/O/power isolation
  • Selectable output sink/source
  • 20 V output loop power supply
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power
  • For orders of 5 or more, call us for lead times

APD8000 UL approved
APD 8000

IsoSplitter ® Signal Splitter
1 Potentiometer Input to 2 DC Outputs


Factory Configured
APD 3393  from $499

Open Datasheet
Download Datasheet
Use any full range 100 Ω to 1 MΩ potentiometer
Specify output range for each channel
2 independent output channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
  • One potentiometer input
  • Two isolated DC output channels
  • Selectable sink/source mA output
  • 20 V output loop power supplies
  • I/O LoopTracker LEDs
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 85-265 VAC, 60-300 VDC
  • D for 9-30 VDC, 10-32 VAC power

Potentiometer IsoSplitter UL approved
APD 3393 Potentiometer IsoSplitter

DuoPak ® 2 Channel Isolated Signal Conditioners


Factory Configured
APD 2000 Series  from $519

Specify input range for each channel
APD 2003 Ch1: DC mV/V/mA Ch2: Potentiometer
APD 2013 Ch1: RTD Ch2: Potentiometer
APD 2033 Ch1: Potentiometer Ch2: Potentiometer
APD 2035 Ch1: Potentiometer Ch2: Strain gauge
APD 2036 Ch1: Potentiometer Ch2: AC mV/V/mA
APD 2037 Ch1: Potentiometer Ch2: Frequency
Specify output range for each channel
2 independent channels
0-1 V to 0-20 V
±1 V to ±10 V
0-1 mA to 0-25 mA, 4-20 mA
  • Optional I/O reversal
  • I/O LoopTracker LEDs
  • Selectable sink/source mA output
  • 20 V output loop power supplies
  • Output test buttons
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount
  • 45 mm wide
  • Universal power 85-265 VAC, 60-300 VDC
  • D for 9-30 VDC, 10-32 VAC power

DuoPak UL approved
APD 2000 Series Potentiometer

Analog To Resistance Converter


Factory Configured
ATR167  call for quote

Open Datasheet
Download Datasheet
Specify input type and range
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance
Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
  • High resolution true analog output
  • 3-wire pot or 2-wire variable resistor output simulation
  • Front zero and span pots
  • Output level LED
  • Full I/O/power isolation
  • Universal power options: 8 VDC to 280 VAC
Typical applications include
  • Convert a thermocouple to RTD signal to match dissimilar existing equipment
  • Automatic gain control
ATR167
ATR167

Analog To Potentiometer Converter


Factory Configured
ATP 168  call for quote

Open Datasheet
Download Datasheet
Specify input type and range
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance
Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
  • Convert a signal to a potentiometer output
  • 3-wire pot or 2-wire variable resistor output simulation
  • 8 bit output resolution (255 count)
  • Front zero and span pots
  • Output level LED
  • Full I/O/power isolation
  • Universal power options: 8 VDC to 280 VAC
Typical applications include
  • Replace mechanical pot used for control of existing machinery
  • Automatic control of instrumentation gain or offset
  • Provide programmable adjustment for delays, filters or time constants.
ATP168
ATP168

Head-Mount Universal Transmitter, Isolated


Field Programmable


Fits DIN Form B Heads
T121  $159 *stock item*

Open Datasheet
Download Datasheet
Open Installation Manual
Download Installation Manual
Click to see ALL Seneca products
Programmable
Input: Pt100 or Ni100, Pt500, Pt1000
J, K, R, S, T, B, E, N
Potentiometer
mVDC, VDC
Selectable Output
Output: 4-20 mA, 20-4 mA
  • Order T121-C for pre-programmed I/O
  • 44 mm dia
  • EASY-USB configuration
  • I/O isolation
  • Low cost
  • DIN B with 5.8mm (0.228"dia) center hole
  • Power: 7 to 30 VDC current loop

T121 CE logo
T121
Programming kitK121
K121
Includes
Converter
Software mini CD (or download latest)
Adapter cable (std USB cable not included)
EASY-USB
EASY-USB

4 Digit 4-20 mA Loop Powered Display


Field Rangeable


S315  $139 *stock item*
S315-IP66  $300

Open Datasheet
Download Datasheet
Open Installation Manual
Download Installation Manual
Click to see ALL Seneca products
Loop Powered Display
Input: 4-20 mA
Display: 4 digit red LED
  • 1/8 DIN panel mount or IP66 housing
  • Scaleable 4 digit display

CE logo
S315
S315