Internationally accepted Swiss precision for optimum energy management.
The deregulation of energy markets and globally increasing environmental awareness define a high degree of responsibility for companies to treat power as a precious resource. Camille Bauer provides a wide spectrum of innovative and highly efficient power measurement and analysis products.
Our extensive product line is manufactured in accordance with individual customer specifications and their functionality is adapted to your requirements in order to guarantee optimum results. Custom-made measuring performance has always been part of our service.
- Sineax Power Products
- Power Meters and Monitors
- Power Analysis
- Power Transducers
- Sineax Software
- Select your model
- See data sheet for ordering info and options
- Call 800-942-0315 for ordering assistance and a quotation
- 3 to 4 week typical lead time (USA customers)
- To place your order
- Call 800-942-0315 for credit card order
- Find your authorized representative
- Call us to find your local distributor
- Set up an account to use a purchase order
- Outside the USA?
Sineax A210 & A220 Multifunction Power Meters
A210/A220/A230/A230s Series BrochureA210/A220 Data Sheet
A210/A220 Instructions
290 V phase-to-neutral,
500 V phase-to-phase, 50/60 Hz
Output: Digital pulse, relay.
Add EMMOD modules for additional I/O capabilities
- A210 1/4 DIN size or A220 full-size DIN
- 19 types of measurements including
- P, Q, S, I~, U~ (rms), cos φ, (PF, 4 quadrants), f, Pint, Qint, Sint
- 3 programmable displays
- Open collector alarm relay and pulse outputs
- Data logging, RS232, and MODBUS with EMMOD 201 option
- Two analog outputs with EMMOD 202 option
- Ethernet interface with EMMOD 203 option
- PROFIBUS interface with EMMOD 204 option
- Hi/Lo electrical rates
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
Sineax A230 & A230s Multifunction Power Meter w. System Load & Harmonics
A210/A220/A230/A230s Series Brochure
A230/A230s Data Sheet
A230/A230s Instructions
A230 CE Declaration
A230s CE Declaration
Output: Digital pulse, relay. See EMMOD modules below for additional I/O capabilities
- A230 full-size DIN or A230s 1/4 DIN
- 19 types of measurements including
- P, Q, S, I~, U~ (rms), cos φ (PF, 4 quadrants), f, Pint, Qint, Sint, THD, harmonics, UNE, unbU
- Three 4-digit programmable displays
- Open collector alarm relay and pulse outputs
- Data logging, RS-232, and MODBUS with optional EMMOD 201
- Two analog outputs with EMMOD 202 option
- Ethernet interface with EMMOD 203 option
- PROFIBUS interface with EMMOD 204 option
- Hi/Lo electrical rates
- Comprehensive mean and max./min. value functions with trend
- System analysis functions (THD, harmonics, asymmetry)
- Higher accuracy
- 24-60 VAC/VDC or 85-230 VAC/VDC powered
EMMOD modules for A210, A220, A230, A230s Multifunction Power Meters
A200Plus Software for EMMOD modulesEMMOD201 RS232/RS485/Datalogging Instructions
EMMOD201 MODBUS Setup Instructions
MODBUS Basics
EMMOD202 Analog Output Module Instructions
EMMOD203 Ethernet Installation Instructions
EMMOD203 Ethernet Interface Instructions
EMMOD204 PROFIBUS Instructions
EMMOD204 PROFIBUS GSD File
EMMOD205 LON Interface Instructions
EMMOD205 LON XIF and APB Type A
EMMOD205 LON XIF and APB Type E
EMMOD206 M-Bus Interface
EMMOD206 Load Calculator xls
Output/Communications
EMMOD201 Switchable RS232/RS485 (Modbus) interface, data logger, digital input
EMMOD202 2 Analog Outputs
EMMOD203 Ethernet interface (Modbus/TCP, HTTP), data logger with timestamp, 2 digital inputs
EMMOD204 Profibus DP interface
EMMOD205 LON interface, digital I/O
EMMOD206 M-Bus interface, digital input
Sineax A-Plus
True RMS Multifunction Power Meter with Power Quality Analysis
A Plus BrochureA Plus Instructions
A Plus Safety Instructions
DIN Rail Adapter
A Plus PROFIBUS Certificate
A Plus Software
CB Manager Software
CB Analyzer Software
CB Analyzer Software Instructions
CB Software Read Me First
A Plus Modbus RTU
A Plus Modbus/TCP
A Plus PROFIBUS GSD Files
Output : Programmable digital pulse, relay, Modbus
- Power quality analysis
- Display 4 variables
- MODBUS standard
- Optional 2 relay and 4 analog outputs, 2 digital I/O
- Optional 2 relay, 6 digital I/O
- Optional data logging
- Alarm contact triggered on any setpoint
- Includes measurement & configuration software
- 100-230 VAC or 24-230 VDC powered
Sineax CAM Multifunction Energy Transducer
CAM BrochureRogowski Sensors Brochure
CAM Data Sheet
CAM Instructions
CAM Instructions for Graphic Display
CAM Safety Instructions
CAM Installation of IEC 61850 option
CAM IEC 61850 Certificate
CB Manager Software
CB Data Analylysis Software
CAM ICD Files
MODBUS Basics
MODBUS Instructions
MODBUS/TCP Instructions
Output/Communications: RS-485 MODBUS, Relay, Up to 4 analog, Digital I/O, USB 2.0 programming interface
- True RMS
- Simultaneous measurement of all 3 phases
- Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
- 85-265 VAC/ 110-265 VDC powered
- Optional 17-90 VDC powered
IEC 61850
Sineax A200 Multifunction Display for DME Power Transducers
Data SheetInstructions
DIN Rail Adapter
Output: 3 digital displays
- 1/4 DIN (96 x 96 mm) display for DME4 transducers
- Triple LED display 14 mm digit height
- Selectable display parameters
- 20-265 VAC/VDC powered
DM5S, DM5F Universal Power Transducer with MODBUS Interface and/or Analog Outputs
DM5 Data SheetDM5 Instructions
MODBUS Basics
MODBUS Instructions
CB Manager Software
Output: Up to 4 analog outputs and/or MODBUS interface
Programmable universal measurement devices for energy distribution and industrial applications. The devices can be quickly set up with CB-Manager software. Versions are availalbe for analog DC current outputs or Modbus. Measurements are done in all four quadrants and can be optimally adapted to the system to be monitored. Both the average time of the measurement and the expected maximum signal level can be configured. Commissioning is very easy and is supported by means of service functions, such as nameplate printing, connection check, measurement acquisition as well as simulation and trimming of the analog outputs.
- DM5F: Fast response version
- System state monitoring: class 0.2
- Energy metering class 0.5S
- Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
- USB PC programming interface
- Configure using CB Manager software
- 24-230 VDC or 100-230 VAC powered