APCS Signal Conditioners, Converters, Isolators, Transmitters
- 1 Year Warranty
- Full I/O/Power Isolated
Click on PDF link below
for product information
Click to see all APCS products
Made in Australia
Call API today for lead time and pricing!
Literature
APCS product brochure
How to select your product
- Open pdf datasheet for your model
- Select model, range, units, options, accessories
- Contact us if you need assistance
Ready to order?
Other ways to order
Other ways to order
- Click here to set up an account
-
Click here to find your authorized dealer or
if you are outside the USA - Call us to find your local authorized distributor
Model
Input/Output
Features
Product
Analog To Resistance Converter
Factory Configured
ATR167 call for quote
Open Datasheet
Download Datasheet
Specify input type and range
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance
Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance
Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
- High resolution true analog output
- 3-wire pot or 2-wire variable resistor output simulation
- Front zero and span pots
- Output level LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
-
Convert a thermocouple to RTD signal to
match dissimilar equipment - Automatic gain control
ATR167
Analog To Potentiometer Converter
Factory Configured
ATP 168 call for quote
Open Datasheet
Download Datasheet
Specify input type and range
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance
Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
Millivolt/Volts
Potentiometer or resistance
Specify output range
Potentiometer: 1k, 2k, 5k, 10k, 20k, 50k, 100k, 200k, custom
- Convert a signal to a potentiometer output
- 3-wire pot or 2-wire variable resistor output simulation
- 8 bit output resolution (255 count)
- Front zero and span pots
- Output level LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
-
Replace mechanical pot used for control of
existing machinery - Automatic control of instrument gain or offset
-
Provide programmable adjustment for delays,
filters or time constants.
ATP168
Process Signal to Bi-Polar DC Signal Converter
Factory Configured
BSC133 call for quote
BSC133 Data Sheet
BSC133 More Information
Specify input type and range
AC/DC current/millivolt/volts
pH/ORP
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
LVDT
Potentiometer or resistance
Specify output type and range
Bi-polar volts; ±1V to ±20V
Bi-polar mA; ±1mA to ±20mA
Output Options
AC/DC current/millivolt/volts
pH/ORP
RTD
Thermocouple
Frequency to 5kHz
Pulse input from proximity sensor
LVDT
Potentiometer or resistance
Specify output type and range
Bi-polar volts; ±1V to ±20V
Bi-polar mA; ±1mA to ±20mA
Output Options
- Output ramp
- External ratio 0.5 - 1.5
- High current output
- Auxiliary supply 24VDC/25mA max
- External bipolar supply
- Peak hold (max. hold 120 min)
- Track and hold (max. hold 120 min)
- Load independent bi-polar output
-
High power output & dither options for
hydraulic applications - Adder or subtractor options
-
Output ramp, external ratio peak hold and
track & hold options - Sensor excitation
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
- Signal conversion
- Hydraulic drive and solenoid actuation
BSC133
DC-DC converter with 5KV Isolation
Factory Configured
HVI237 call for quote
Open Datasheet
Download Datasheet
Specify input type and range
1 to 100mADC
100 to 100VDC
100V to 2000VDC
0-5A true RMS
Selectable range option: +/-100mV, 100mV, +/-250mV, 0-250mV
Selectable range option: 150 VAC, 300VAC true RMS
Specify output type and range
One or two outputs available (not isolated from each other)
4-20mA (specify sink or source)
0-10V
Custom output ranges
Customized response time 250µs to 5s, 500mS standard
1 to 100mADC
100 to 100VDC
100V to 2000VDC
0-5A true RMS
Selectable range option: +/-100mV, 100mV, +/-250mV, 0-250mV
Selectable range option: 150 VAC, 300VAC true RMS
Specify output type and range
One or two outputs available (not isolated from each other)
4-20mA (specify sink or source)
0-10V
Custom output ranges
Customized response time 250µs to 5s, 500mS standard
- Convert a High Voltage signal to a DC output
- Front zero and span pots
- Output level LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
HVI237
Specify input type and range
DC voltage to 10 V
DC mMilliamps to 20 mA
DC voltage up to 2kV
DC current to 10A
Specify relay output type
SPDT relays
Specify NO or NC contacts
DC voltage to 10 V
DC mMilliamps to 20 mA
DC voltage up to 2kV
DC current to 10A
Specify relay output type
SPDT relays
Specify NO or NC contacts
- Input up to 2 kVDC and 10 ADC
- Contacts rated at 10A/250VAC
- Sensor excitation
- Front setpoint adjustment
- Status LED
- Universal power options: 8 VDC to 280 VAC
- Multiple level process alarm
TRA173
Specify input range
1mS/cm to 1000mS/cm
Please provide sensor K factor
Specify output type and range
Voltage to 10 V
Milliamps to 50 mA
1mS/cm to 1000mS/cm
Please provide sensor K factor
Specify output type and range
Voltage to 10 V
Milliamps to 50 mA
- Convert a conductivity sensor signal to a DC output
- Use with any conductivity cell with known K factor
- Temperature compensation option
- Front zero and span pots
- Output level LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
- Interface with conductivity cells
- Detecting contamination
- Salinity monitor
CDT128
Specify LVDT information
Brand
Model
Stroke: mm
Sensitivity: mV/V/mm
Frequency: Hz
Specify output type and range
Unipolar or Bi-polar volts up to
10 V or milliamps to 20 mA
Brand
Model
Stroke: mm
Sensitivity: mV/V/mm
Frequency: Hz
Specify output type and range
Unipolar or Bi-polar volts up to
10 V or milliamps to 20 mA
- Convert an LVDT output to DC signal
- Any type of LVDT input
- Output ramp option
- Front zero and span pots
- Output level LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
-
Interface to LVDT (Linearly Variable
Differential Transformer) - Position monitoring
LVDT149
Specify input type and range
0 - 14pH
2 - 12pH
4 - 10pH
5 - 9pH
6 - 8pH
6.5 - 7.5pH
Other pH (specify)
0 - 1000mV redox (ORP)
Other redox (ORP) (specify)
Selective ion electrode
Specify output type and range
Voltage to 10 V
Milliamps to 50 mA
0 - 14pH
2 - 12pH
4 - 10pH
5 - 9pH
6 - 8pH
6.5 - 7.5pH
Other pH (specify)
0 - 1000mV redox (ORP)
Other redox (ORP) (specify)
Selective ion electrode
Specify output type and range
Voltage to 10 V
Milliamps to 50 mA
- Convert pH/ORP to a DC signal
- Wide range of pH and ORP probe inputs
- High input impedance
- Temperature compensation optional
- Front zero and span pots
- Output level LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
- Wastewater and water treatment monitoring
- Detecting contamination
- Salinity monitor actuator feedback
PHT129
Zero Speed (Stall) Monitor
Factory Configured
STM156 call for quote
Open Datasheet
Download Datasheet
Specify input type
Frequency input
Low level sine or sawtooth (200mVpp - 20Vpp)
24VDC pulse external source (0.2 - 50VDC)
NAMUR proximity sensor or contact (8V)
3-wire NPN proximity sensor 15V auxiliary
3-wire PNP proximity sensor 15V auxiliary
3-wire NPN proximity sensor 24V auxiliary
3-wire PNP proximity sensor 24V auxiliary
2-wire 24VDC/AC proximity sensor 24V auxiliary
Specify output type and options
Adjustable trip point and delays
One or two relays
Trip speed delay time range
Start up delay time range
External control options
Frequency input
Low level sine or sawtooth (200mVpp - 20Vpp)
24VDC pulse external source (0.2 - 50VDC)
NAMUR proximity sensor or contact (8V)
3-wire NPN proximity sensor 15V auxiliary
3-wire PNP proximity sensor 15V auxiliary
3-wire NPN proximity sensor 24V auxiliary
3-wire PNP proximity sensor 24V auxiliary
2-wire 24VDC/AC proximity sensor 24V auxiliary
Specify output type and options
Adjustable trip point and delays
One or two relays
Trip speed delay time range
Start up delay time range
External control options
- Relay contact output
- Front adjustments for trip speed and start-up delay
- Status LED
- Full I/O/power isolation
- Universal power options: 8 VDC to 280 VAC
- Under speed alarm
- Broken conveyor belt alarm
- Machinery jam alarm
- Stalled motor alarm
STM156