Electric Power Monitors and Transducers
Heavy current engineering

Internationally accepted Swiss precision for optimum energy management.

The deregulation of energy markets and globally increasing environmental awareness define a high degree of responsibility for companies to treat power as a precious resource. Camille Bauer provides a wide spectrum of innovative and highly efficient power measurement and analysis products.

Our extensive product line is manufactured in accordance with individual customer specifications and their functionality is adapted to your requirements in order to guarantee optimum results. Custom-made measuring performance has always been part of our service.

  • Sineax Power Products
  • Power Meters and Monitors
  • Power Analysis
  • Power Transducers
  • Sineax Software
How to Order
  1. Select your model
  2. See data sheet for ordering info and options
  3. Call 800-942-0315 for ordering assistance and a quotation
  4. 3 to 4 week typical lead time (USA customers)
  5. To place your order
Model/Downloads
Input/Output
Features
Product
Multi-Function Power Meters

DM5S, DM5F Universal Power Transducer with MODBUS Interface and/or Analog Outputs

DM5 Data Sheet
DM5 Instructions
MODBUS Basics
MODBUS Instructions
CB Manager Software
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz
Output: Up to 4 analog outputs and/or MODBUS interface

Programmable universal measurement devices for energy distribution and industrial applications. The devices can be quickly set up with CB-Manager software. Versions are availalbe for analog DC current outputs or Modbus. Measurements are done in all four quadrants and can be optimally adapted to the system to be monitored. Both the average time of the measurement and the expected maximum signal level can be configured. Commissioning is very easy and is supported by means of service functions, such as nameplate printing, connection check, measurement acquisition as well as simulation and trimming of the analog outputs.

  • DM5F: Fast response version
  • System state monitoring: class 0.2
  • Energy metering class 0.5S
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, f
  • USB PC programming interface
  • Configure using CB Manager software
  • 24-230 VDC or 100-230 VAC powered
DM5
profibus logo CE logo UL
Input: 0-1A, 0-5 A from CT or Two 4-20 mA, 57-400 V phase-to-neutral, 100-693 V phase-to-phase, 50/60 Hz, Digital I/O
Output/Communications: RS-485 MODBUS, Relay, Up to 4 analog, Digital I/O, USB 2.0 programming interface
  • True RMS
  • Simultaneous measurement of all 3 phases
  • Measures P, Q or S, I ~, U ~ (RMS), cos φ, sin φ, LF, PF, QF, LF, f, THD, TDD, VAR
  • 85-265 VAC/ 110-265 VDC powered
  • Optional 17-90 VDC powered
CAM
CAM with display
Modbus

IEC 61850

CE logo

Sineax A200 Multifunction Display for DME Power Transducers

Data Sheet
Instructions
DIN Rail Adapter
Input: Serial data from DME4 series
Output: 3 digital displays
  • 1/4 DIN (96 x 96 mm) display for DME4 transducers
  • Triple LED display 14 mm digit height
  • Selectable display parameters
  • 20-265 VAC/VDC powered
A200 CE logo Din bracket
Power Transducers
Input: 0-0.8 A to 0-1.2 A or, 0-4 A to 0-6 A, 100-690 V, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • 3-Phase with Balanced or Unbalanced Load
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
P 530
CE logo CSA logo Germanischer Lloyd
Current Transducers
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
I 538
CE logo CSA logo Germanischer Lloyd
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Powered from Measuring Source
I 542
CE logo CSA logo Germanischer Lloyd
Input: 0-0.8 A to 0-1.2 A or 0-4 A to 0-6 A from CT , 50/60 or 400 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
I 552
CE logo CSA logo Germanischer Lloyd
Voltage Transducers
Input: 0-50 V to 0-600 V, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
U 539
CE logo CSA logo Germanischer Lloyd
Input: 0-20 V to 0-600 V, 50/60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sinusoidal Input
  • Powered from Measuring Source
U 543
CE logo CSA logo Germanischer Lloyd
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
U 553
CE logo CSA logo Germanischer Lloyd

Sineax U 554 True RMS AC Voltage Transducer

Data Sheet
Instructions
Input: 0-20 V to 0-690 V, 50/60 or 400 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, 0-1 V to 2-10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Special Version to Allow Zero Offset
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
U 554
CE logo
Frequency Transducers
Input: 10 V to 690 V, 10 to 1500 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
F 534
CE logo CSA logo Germanischer Lloyd
Input: 10 V to 690 V, 10 to 1500 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, to ±10 V
  • Measure Δf Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
F 535
CE logo CSA logo Germanischer Lloyd
Phase Angle (Power Factor) Transducers
Input: 1 or 5 A from CT, 10 V to 690 V, 16 to 400 Hz, 0.5 cap. 1.ind. 0.5 cos Φ
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • Measure Single or 3-Phase Balanced
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
g 536
CE logo CSA logo Germanischer Lloyd

Sineax G 537 Phase Angle Difference Transducer

Instructions
CSA Certificate
GL Certificate for Shipboard Use
Input: 10 V to 690 V, 50 or 60 Hz
Output: 0-1 mA to 0-20mA, 1-5 mA to 4-20 mA, ±1 mA to ±20 mA, 0-1 V to 2-10 V, ±10 V
  • Measure ΔΦ Between 2 Synchronized Supplies
  • Sine, Rectangular or Distorted Wave Forms
  • Available as Measuring Source Powered to 230 V
  • 24-60 VAC/VDC or 85-230 VAC/VDC Powered
G 537