Analog DC Voltage and Current Alarms

lifetime warranty
  • Lifetime Warranty on API Modules
  • LoopTracker ® Input LED
  • Alarm Status LEDs
  • Hot-Swappable Plug-In Design
  • User Adjustable Setpoint(s)
  • Push to Test/Reset Alarms
  • Full I/O/Power Isolation

Click on PDF links below
for product information

How to Order

  1. Select a model
  2. See data sheet for ordering info and options
  3. Note that options affect pricing
  4. Request a quote via chat or call us
  5. 2-5 day typical lead time + shipping time
  6. 5-10 day lead time for quantities of 5 or more + shipping time
  7. To place your order
Model
Input/Output
Features
Product

DC Input Alarm Trips


Factory Configured
API 1000 G  from $269
API 1020 G  from $299

Open Datasheet
Download Datasheet
Specify input range
Factory configured
0-100 mVDC to 0-300 VDC
0-1 mADC to 0-900 mADC
API 1000 G Single Alarm Trip
One DPDT contact set, adjustable deadband
Standard: HI alarm
Optional: LO alarm
API 1020 G Dual Alarm Trip
Two SPDT contact sets, 1% deadband
Standard: HI/LO alarms, normal acting
Optional: LO/HI, HI/HI, LO/LO alarms
  • User adjustable setpoint(s)
  • 8 Amp contacts
  • Hot-swappable plug-in design
  • Replaces Action AP 1000 and AP 1020
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO
  • Output test button
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option: 85-265 VAC, 60-300 VDC power (+$60)
  • D option: 9-30 VDC power (+$60)


Api 1000 G
API 1000 G, API 1020 G

DC Input Alarm Trips


Factory Configured
APD 1000   from $289
APD 1020   from $329

Open Datasheet
Download Datasheet
Specify input range
Factory configured
0-100 mVDC to 0-300 VDC
0-1 mADC to 0-20 mADC, 4-20 mA
APD 1000 Single Alarm Trip
Dual SPDT contact sets
Standard: HI alarm, non-latching, normal acting
See data sheet for alarm options
APD 1020 Dual Alarm Trip
2 independent SPDT contact sets
Standard: HI/LO alarms, non-latching, normal acting
See data sheet for alarm options
  • User adjustable setpoint(s)
  • User adjustable deadband(s)
  • Selectable sink/source mA input
  • 15 V input loop power supply
  • 8 Amp SPDT contacts
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO, band alarm
  • Optional reverse acting
  • Optional latching alarms
  • Push to test/reset
  • Remote push to test/reset
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount without tools
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power


APD 1000 UL approved
APD 1000, APD 1020

4-20 mA Input Alarm Trips
With Input Loop Power Supply


Factory Configured
API 1005 G  from $279
API 1025 G  from $319

Open Datasheet
Download Datasheet
4-20 mA input range
Factory configured
API 1005 G Single Alarm Trip
One DPDT contact set, adjustable deadband
Standard: HI alarm
Optional: LO alarm
API 1025 G Dual Alarm Trip
Two SPDT contact sets, 1% deadband
Standard: HI/LO alarms, normal acting
Optional: LO/HI, HI/HI, LO/LO alarms
  • 8 Amp contacts
  • Hot-swappable plug-in design
  • Replaces Action AP 1005 and AP 1025
  • Input LoopTracker LED
  • Alarm status LEDs
  • Alarm options: LO, HI/HI, LO/LO
  • Output test button
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option: 85-265 VAC, 60-300 VDC power (+$60)
  • D option: 9-30 VDC power (+$60)


Api 1005G
API 1005 G, API 1025 G

DC Input Alarm Trips


Field Selectable Minuteman Setup


API 1080 G  from $289
API 1090 G  from $329

Open Datasheet
Download Datasheet
24 Input Ranges
0-50 mV to 0-10 V
±5 V, ±10 V
0-1 mA to 0-20 mA, 4-20 mA
API 1080 G Field Configurable Single Alarm
One DPDT contact set
Adjustable setpoint and deadband
API 1090 G Field Configurable Dual Alarms
2 independent SPDT contact sets
Two adjustable setpoints each with deadband
  • User adjustable setpoint(s)
  • User adjustable deadband(s)
  • User selectable alarm logic
  • 8 Amp SPDT contacts
  • Alarm status LEDs
  • Selectable sink/source mA input
  • 15 V input loop power supply
  • Input LoopTracker LED
  • Push to test/reset
  • Full I/O/power isolation
  • Hot-swappable plug-in design
  • Uses API-011 11-pin socket
  • 115 VAC powered
  • A230 option for 230 VAC
  • P option: 85-265 VAC, 60-300 VDC power (+$60)
  • D option: 9-30 VDC power (+$60)

Api 1090 G
API 1080 G, API 1090 G
Socket sold separately

DC Input Alarm Trips


Field Selectable Minuteman Setup


APD 1080  from $289
APD 1090  from $299

Open Datasheet
Download Datasheet
24 Input Ranges
0-50 mV to 0-10 V
±5 V, ±10 V
0-1 mA to 0-20 mA, 4-20 mA
APD 1080 Field Configurable Single Alarms
Two DPST contact sets
Adjustable setpoint and deadband
2 form A (NO), 2 form B (NC) contact sets
May be field wired for form C operation
APD 1090 Field Configurable Dual Alarms
2 independent SPDT contact sets
Two adjustable setpoints each with deadband
SP 1: form A (NO) and form B (NC) contacts
SP 2: form A (NO) and form B (NC) contacts
May be field wired for form C operation
  • User adjustable setpoint(s)
  • User adjustable deadband(s)
  • User selectable alarm logic
  • 8 Amp SPDT contacts
  • Alarm status LEDs
  • Selectable sink/source mA input
  • 15 V input loop power supply
  • Input LoopTracker LED
  • Push to test/reset
  • Full I/O/power isolation
  • Removable plugs
  • DIN rail mount without tools
  • Universal power 85-265 VAC, 60-300 VDC
  • D option for 9-30 VDC, 10-32 VAC power

APD1080 UL approved
APD 1080, APD 1090

Triple Trip Alarm


Factory Configured
TRA173  call for quote

Open Datasheet
Download Datasheet
Specify input type and range
DC voltage to 10 V
DC mMilliamps to 20 mA
DC voltage up to 2kV
DC current to 10A
Specify relay output type
SPDT relays
Specify NO or NC contacts
  • Input up to 2 kVDC and 10 ADC
  • Contacts rated at 10A/250VAC
  • Sensor excitation
  • Front setpoint adjustment
  • Status LED
  • Universal power options: 8 VDC to 280 VAC
Typical applications include
  • Multiple level process alarm
TRA173
TRA173

DC Current Switches


CS-DC-1S-24  $140
CS-DC-2S-24  $135 *stock item*
CS-DC-1S-12  $140
CS-DC-2S-12  $135

Open Datasheet
Download Datasheet
Email Datasheet Link
Input
0-100 Amps DC
Output CS-DC-1S-24
SPDT relay,
5 A @ 240 VAC / 3 A @ 30 VDC
Output CS-DC-2S-24
NO Solid state relay,
0.3 A @ 135 VAC/DC
Output CS-DC-1S-12
SPDT relay,
5 A @ 240 VAC / 3 A @ 30 VDC
Output S-DC-2S-12
NO Solid state relay,
0.3 A @ 135 VAC/DC
Power CS-DC-1S-24, CS-DC-2S-24
20-28 VAC/DC
Power CS-DC-1S-12, CS-DC-2S-12
12 VAC/DC ±10%
  • Adjustable 2 to 100 Amp setpoint
  • Low voltage AC or DC powered
  • LED power and status indicators
  • Solid core
  • 5-Year warranty
CE
apicsdc
CS-DC Series
Full Website